3 HP cabinet table saw
The 3 HP cabinet saw needs a 240V circuit. The Amazon pick is the nearest contractor-class alternative; check its listing for voltage, since the saving is only real if it runs on a circuit you already have.
Machine fit · Grizzly G1023RL
The Grizzly G1023RL measures 66 x 47 in (5.5 x 3.9 ft) and weighs 508 lb, runs on 240V at 14 A. It fits with operator room in 6 of our 6 garage sizes, the smallest being the 12x20 one-car, and it fits with a sedan parked inside from the 20x20 two-car up.
From the grizzly.com listing: 32 in right rip, 3 in depth at 90 degrees, table 40 x 27, 34 in table height, base footprint 20-1/2 in square. Owner-rated 4.8 on grizzly.com (137 reviews).
| Garage | Alone, operator room | Car parked, working | Car parked, stored | Share of floor |
|---|---|---|---|---|
| One-car, 12 x 20 | yes | no | no | 9% |
| One-car, 12 x 22 | yes | no | no | 8% |
| Two-car, 20 x 20 | yes | yes | yes | 5% |
| Two-car, 22 x 22 | yes | yes | yes | 4% |
| Two-car, 24 x 24 | yes | yes | yes | 4% |
| Three-car, 32 x 24 | yes | yes | yes | 3% |
"Operator room" keeps 30 in clear around the machine, and "stored" drops that zone, for a machine you roll out only when the car is gone. Both leave a 24 in apron in front of the overhead door and a 30 in walk-around beside any parked sedan. In a 12 x 20 ft garage with a car inside, this machine has to be stored elsewhere.
This is a stock-fed machine. For 8 ft boards it needs about 16 ft of clear line; the 12 x 20 bay offers 20 ft with nothing else in it and 22 ft in a 22 x 22. Where the bay is short, the answer is an outfeed support that folds away or a mobile base that rolls the machine to the open middle.
Same job, two ways to buy, with one line on when each wins.
The 3 HP cabinet saw needs a 240V circuit. The Amazon pick is the nearest contractor-class alternative; check its listing for voltage, since the saving is only real if it runs on a circuit you already have.
Prices change often and Grizzly runs sales, so the buttons show current prices.
Prices change often; the button shows today's price on Amazon.
The machine, its base, its circuit parts and what goes beside it, as one list. Plus a few short emails, then a couple a month at most.
Unsubscribe anytime. You can also just read the checklist on this site.Yes, in a 12 x 20 ft one-car garage with no vehicle it fits with its operator zone clear and uses 9 percent of the floor. With a sedan parked inside it does not fit at all.
It draws 14 A at 240V (listing), so a 20 A breaker with 12 AWG copper covers the 125 percent rule. On NEC table amps for 3 HP the circuit comes out to a 25 A breaker and 10 AWG copper over a 30 ft run. A licensed electrician confirms the circuit before you wire.
This page is researched guidance, not professional electrical, engineering or safety advice. Circuits, loads and clearances depend on your house, your service and your town: have a licensed electrician confirm any wiring, and check local code and each manufacturer's manual before you act.