3 HP cyclone collector (240V)
Nothing on Amazon in our catalog matches a 3 HP, 1654 CFM cyclone, so this one is Grizzly-direct only. It needs a 240V circuit and about 400 lb of freight.
Machine fit · Grizzly G0441
The Grizzly G0441 measures 32.9 x 32.9 in (2.7 x 2.7 ft) and weighs 400 lb, runs on 240V at 22 A. It fits with operator room in 6 of our 6 garage sizes, the smallest being the 12x20 one-car, and it fits with a sedan parked inside from the 12x22 one-car up.
From the grizzly.com listing: 1654 CFM at 2.0 in SP, 8 in inlet, 55 gal drum, rated for three machines at once.
| Garage | Alone, operator room | Car parked, working | Car parked, stored | Share of floor |
|---|---|---|---|---|
| One-car, 12 x 20 | yes | no | no | 3% |
| One-car, 12 x 22 | yes | yes | yes | 3% |
| Two-car, 20 x 20 | yes | yes | yes | 2% |
| Two-car, 22 x 22 | yes | yes | yes | 2% |
| Two-car, 24 x 24 | yes | yes | yes | 1% |
| Three-car, 32 x 24 | yes | yes | yes | 1% |
"Operator room" keeps 12 in clear around the machine, and "stored" drops that zone, for a machine you roll out only when the car is gone. Both leave a 24 in apron in front of the overhead door and a 30 in walk-around beside any parked sedan. In a 12 x 20 ft garage with a car inside, this machine has to be stored elsewhere.
Same job, two ways to buy, with one line on when each wins.
Nothing on Amazon in our catalog matches a 3 HP, 1654 CFM cyclone, so this one is Grizzly-direct only. It needs a 240V circuit and about 400 lb of freight.
Prices change often and Grizzly runs sales, so the buttons show current prices.
Prices change often; the button shows today's price on Amazon.
The machine, its base, its circuit parts and what goes beside it, as one list. Plus a few short emails, then a couple a month at most.
Unsubscribe anytime. You can also just read the checklist on this site.Yes, in a 12 x 20 ft one-car garage with no vehicle it fits with its operator zone clear and uses 3 percent of the floor. With a sedan parked inside it does not fit at all.
It draws 22 A at 240V (listing), so a 30 A breaker with 10 AWG copper covers the 125 percent rule. On NEC table amps for 3 HP the circuit comes out to a 25 A breaker and 10 AWG copper over a 30 ft run. A licensed electrician confirms the circuit before you wire.