Benchtop drill press
Both are benchtop drill presses on a 120V cord. The Grizzly lists a 15 in swing with an LED light and laser guide; the Amazon pick is a 12 in size at a lower entry cost.
Machine fit · Grizzly T34608
The Grizzly T34608 measures 19.5 x 12 in (1.6 x 1.0 ft) and weighs 127 lb, runs on 120V at 5.3 A. It fits with operator room in 6 of our 6 garage sizes, the smallest being the 12x20 one-car, and it fits with a sedan parked inside from the 12x20 one-car up.
From the grizzly.com listing: 15-1/4 in swing, 12 speeds, 10-9/16 in square table, footprint 19-1/2 x 12, 42 in tall.
| Garage | Alone, operator room | Car parked, working | Car parked, stored | Share of floor |
|---|---|---|---|---|
| One-car, 12 x 20 | yes | yes | yes | 1% |
| One-car, 12 x 22 | yes | yes | yes | 1% |
| Two-car, 20 x 20 | yes | yes | yes | 0% |
| Two-car, 22 x 22 | yes | yes | yes | 0% |
| Two-car, 24 x 24 | yes | yes | yes | 0% |
| Three-car, 32 x 24 | yes | yes | yes | 0% |
"Operator room" keeps 24 in clear around the machine, and "stored" drops that zone, for a machine you roll out only when the car is gone. Both leave a 24 in apron in front of the overhead door and a 30 in walk-around beside any parked sedan.
Same job, two ways to buy, with one line on when each wins.
Both are benchtop drill presses on a 120V cord. The Grizzly lists a 15 in swing with an LED light and laser guide; the Amazon pick is a 12 in size at a lower entry cost.
Prices change often and Grizzly runs sales, so the buttons show current prices.
Prices change often; the button shows today's price on Amazon.
The machine, its base, its circuit parts and what goes beside it, as one list. Plus a few short emails, then a couple a month at most.
Unsubscribe anytime. You can also just read the checklist on this site.Yes, in a 12 x 20 ft one-car garage with no vehicle it fits with its operator zone clear and uses 1 percent of the floor. It also fits with a sedan parked inside.
It draws 5.3 A at 120V (listing), so a 15 A breaker with 14 AWG copper covers the 125 percent rule. On NEC table amps for 0.75 HP the circuit comes out to a 20 A breaker and 12 AWG copper over a 30 ft run. A licensed electrician confirms the circuit before you wire.