7 x 27 mill/drill
Both are 7 x 27 class benchtop mills with an R-8 spindle. The Grizzly G0704 ships with a stand and a listed weight of 372 lb.
Machine fit · Grizzly G0704
The Grizzly G0704 measures 36 x 30 in (3.0 x 2.5 ft) and weighs 372 lb, runs on 120V at 12 A. It fits with operator room in 6 of our 6 garage sizes, the smallest being the 12x20 one-car, and it fits with a sedan parked inside from the 12x22 one-car up.
From the grizzly.com listing: R-8 spindle, table 7-1/16 x 26-5/8, 18-7/8 in table travel; the briefs do not give a footprint, read the listing.
| Garage | Alone, operator room | Car parked, working | Car parked, stored | Share of floor |
|---|---|---|---|---|
| One-car, 12 x 20 | yes | no | no | 3% |
| One-car, 12 x 22 | yes | yes | yes | 3% |
| Two-car, 20 x 20 | yes | yes | yes | 2% |
| Two-car, 22 x 22 | yes | yes | yes | 2% |
| Two-car, 24 x 24 | yes | yes | yes | 1% |
| Three-car, 32 x 24 | yes | yes | yes | 1% |
"Operator room" keeps 30 in clear around the machine, and "stored" drops that zone, for a machine you roll out only when the car is gone. Both leave a 24 in apron in front of the overhead door and a 30 in walk-around beside any parked sedan. In a 12 x 20 ft garage with a car inside, this machine has to be stored elsewhere.
Same job, two ways to buy, with one line on when each wins.
Both are 7 x 27 class benchtop mills with an R-8 spindle. The Grizzly G0704 ships with a stand and a listed weight of 372 lb.
Prices change often and Grizzly runs sales, so the buttons show current prices.
Prices change often; the button shows today's price on Amazon.
The machine, its base, its circuit parts and what goes beside it, as one list. Plus a few short emails, then a couple a month at most.
Unsubscribe anytime. You can also just read the checklist on this site.Yes, in a 12 x 20 ft one-car garage with no vehicle it fits with its operator zone clear and uses 3 percent of the floor. With a sedan parked inside it does not fit at all.
It draws 12 A at 120V (listing), so a 15 A breaker with 14 AWG copper covers the 125 percent rule. On NEC table amps for 1 HP the circuit comes out to a 20 A breaker and 12 AWG copper over a 30 ft run. A licensed electrician confirms the circuit before you wire.
This page is researched guidance, not professional electrical, engineering or safety advice. Circuits, loads and clearances depend on your house, your service and your town: have a licensed electrician confirm any wiring, and check local code and each manufacturer's manual before you act.