2 HP canister dust collector (240V)
The Grizzly G0548ZP is a 2 HP, 1700 CFM single-stage collector with a 1 micron canister and needs a 240V circuit. The Amazon pick is a 1 HP class bag machine that plugs into 120V and moves far less air.
Machine fit · Grizzly G0548ZP
The Grizzly G0548ZP measures 37.4 x 31.5 in (3.1 x 2.6 ft) and weighs 150 lb, runs on 240V at 9 A. It fits with operator room in 6 of our 6 garage sizes, the smallest being the 12x20 one-car, and it fits with a sedan parked inside from the 12x22 one-car up.
From the grizzly.com listing: 1700 CFM, 10 in maximum static pressure, 1 micron canister 19-5/8 in diameter, 12-3/4 in aluminum impeller, 4-1/2 cu ft bag, 83 to 85 dB.
| Garage | Alone, operator room | Car parked, working | Car parked, stored | Share of floor |
|---|---|---|---|---|
| One-car, 12 x 20 | yes | no | no | 3% |
| One-car, 12 x 22 | yes | yes | yes | 3% |
| Two-car, 20 x 20 | yes | yes | yes | 2% |
| Two-car, 22 x 22 | yes | yes | yes | 2% |
| Two-car, 24 x 24 | yes | yes | yes | 1% |
| Three-car, 32 x 24 | yes | yes | yes | 1% |
"Operator room" keeps 12 in clear around the machine, and "stored" drops that zone, for a machine you roll out only when the car is gone. Both leave a 24 in apron in front of the overhead door and a 30 in walk-around beside any parked sedan. In a 12 x 20 ft garage with a car inside, this machine has to be stored elsewhere.
Same job, two ways to buy, with one line on when each wins.
The Grizzly G0548ZP is a 2 HP, 1700 CFM single-stage collector with a 1 micron canister and needs a 240V circuit. The Amazon pick is a 1 HP class bag machine that plugs into 120V and moves far less air.
Prices change often and Grizzly runs sales, so the buttons show current prices.
Prices change often; the button shows today's price on Amazon.
The machine, its base, its circuit parts and what goes beside it, as one list. Plus a few short emails, then a couple a month at most.
Unsubscribe anytime. You can also just read the checklist on this site.Yes, in a 12 x 20 ft one-car garage with no vehicle it fits with its operator zone clear and uses 3 percent of the floor. With a sedan parked inside it does not fit at all.
It draws 9 A at 240V (listing), so a 15 A breaker with 14 AWG copper covers the 125 percent rule. On NEC table amps for 2 HP the circuit comes out to a 15 A breaker and 14 AWG copper over a 30 ft run. A licensed electrician confirms the circuit before you wire.
This page is researched guidance, not professional electrical, engineering or safety advice. Circuits, loads and clearances depend on your house, your service and your town: have a licensed electrician confirm any wiring, and check local code and each manufacturer's manual before you act.