GarageShopCalcBuild Your Dream Garage

Sizing

How many amps does a mixed shop with a car parked need in a garage

The mixed shop with a car parked package that fits a 22 x 22 ft garage needs 5 circuits (0 at 240V), about 22 A of demand on a 240V-equivalent basis, and a 60 A subpanel to ask your electrician about.

The circuit list

Circuits for the mixed shop with a car parked package
CircuitVoltsBreakerWireReceptacle
Jobsite table saw on a stand120 V20 A12 AWGNEMA 5-20R
14 in bandsaw120 V20 A12 AWGNEMA 5-20R
Tool bench (Planer, Drill press)120 V20 A12 AWGNEMA 5-20R
Shop vac with cyclone separator120 V20 A12 AWGNEMA 5-20R
Shared bench circuit 1120 V20 A12 AWGNEMA 5-20R (several)

240V machines each get a dedicated circuit sized at 125 percent of their running amps; 120V machines at 10 A or more get their own 20 A circuit; small loads share bench circuits. Wire is copper on the NM-B ampacity column (NEC Table 310.16, 60 C). These are planning sizes: a licensed electrician confirms every one.

Why that subpanel

Connected load adds to 29 A in 240V-equivalent terms, but a shop rarely runs everything at once: counting the largest load in full and the rest at a diversity factor gives about 22 A, and with the 125 percent rule a 60 A subpanel. The package is: Jobsite saw, Bandsaw, Tool bench, Vac + separator, 4 ft bench, Shelving. Machines on mobile bases so the car still sleeps inside.

Use the workshop amps calculator to change the machines, and open the 22 x 22 mixed shop with a car parked layout to see where each one sits.

Shop for this size

Matched to the result above.

Prices change often; the button shows today's price on Amazon.

Get the garage shop planning checklist

One printable page: measure the bay, count the circuits, list the machines, check the floor. Plus a few short emails, then a couple a month at most.

Unsubscribe anytime. You can also just read the checklist on this site.

Subpanel by trade: the other answers

Frequently asked questions

Do I need 240V for a mixed shop with a car parked?

Not for the machines in this package: they all run on 120V. Heaters, large compressors, collectors over 2 HP and most welders are happier on 240V; the 240V circuit calculator sizes each.

This page is researched guidance, not professional electrical, engineering or safety advice. Circuits, loads and clearances depend on your house, your service and your town: have a licensed electrician confirm any wiring, and check local code and each manufacturer's manual before you act.