Sizing

What size heater for a 22x22 two-car garage workshop

A 22 x 22 ft garage with 9 ft ceilings (484 sq ft, 4,356 cu ft) needs about 15,500 BTU per hour, a 4.5 kW electric heater on a 25 A, 240V circuit, to hold 55F when it is 10F outside with R-13 walls and a bare ceiling. Insulate the ceiling and door and it falls to about 5,500 BTU; leave it bare in a cold snap and it climbs to 34,500.

Heat needed to hold 55F in a 22x22 two-car garage

Heat load by insulation and outdoor temperature, 22 x 22 ft
Insulation30F outside10F outside-10F outside
Bare shop: no insulation, steel door, leaky13,500 BTU, 4.0 kW24,000 BTU, 7.0 kW34,500 BTU, 10.5 kW
Typical: R-13 walls, bare ceiling, steel door8,500 BTU, 2.5 kW15,500 BTU, 4.5 kW22,500 BTU, 6.5 kW
Upgraded: R-19 walls, R-30 ceiling, insulated door4,500 BTU, 1.5 kW7,500 BTU, 2.5 kW11,000 BTU, 3.5 kW
Tight: R-19, R-38, insulated door, sealed3,500 BTU, 1.0 kW5,500 BTU, 2.0 kW8,000 BTU, 2.5 kW

Each cell is heat lost through the exposed walls, ceiling and overhead door plus the heat needed to warm air that leaks in, for a 9 ft ceiling and one 16 ft door. The kW is the same load converted at 3.412 BTU per watt and rounded up to the next 500 W. U-values and air changes are shop conventions, and slab edge loss is ignored.

The circuit that heater needs

A 4.5 kW heater pulls 18.8 A at 240V. A heater runs for hours, so size the conductor for 125 percent of that: 23.4 A, which means a 25 A breaker and 10 AWG copper. Add it to the other circuits in the shop before you price a subpanel: the workshop amps calculator does the sum. Many garage heaters come with a NEMA 14-50 plug; check the plug against the receptacle you will install, and have a licensed electrician confirm the circuit.

If you would rather burn gas in a 22x22 two-car

A vented gas unit heater at 80 percent efficiency needs about 20,000 BTU per hour of input for the typical case above. That is a size to look for, not a recommendation to buy the biggest: an oversized unit short-cycles. Combustion heaters in a garage with a parked car need real ventilation and a carbon monoxide alarm, and an unvented radiant heater does not belong in a closed bay at all.

Shop for this size

Matched to the result above.

Prices change often; the button shows today's price on Amazon.

Get the garage shop planning checklist

One printable page: measure the bay, count the circuits, list the machines, check the floor. Plus a few short emails, then a couple a month at most.

Unsubscribe anytime. You can also just read the checklist on this site.

Heater by garage size: the other answers

Frequently asked questions

Is a 5,000 W heater enough for a 22x22 two-car garage?

A 5 kW heater delivers about 17,000 BTU per hour. For this garage the typical case at 10F outside needs about 15,500 BTU, so 5 kW is enough unless you insulate the ceiling and door first.

Do I need a 240V heater, or will a 120V space heater do?

A 1,500 W 120V heater makes about 5,100 BTU per hour, which is a fraction of this garage's load. 240V units move more heat per amp and per circuit, which is why a garage shop usually gets a dedicated 240V heater circuit.

This page is researched guidance, not professional electrical, engineering or safety advice. Circuits, loads and clearances depend on your house, your service and your town: have a licensed electrician confirm any wiring, and check local code and each manufacturer's manual before you act.